Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Harm Reduct J ; 21(1): 11, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218980

RESUMO

BACKGROUND: Shifts in the US drug supply, including the proliferation of synthetic opioids and emergence of xylazine, have contributed to the worsening toll of the overdose epidemic. Drug checking services offer a critical intervention to promote agency among people who use drugs (PWUD) to reduce overdose risk. Current drug checking methods can be enhanced to contribute to supply-level monitoring in the USA, overcoming the selection bias associated with existing supply monitoring efforts and informing public health interventions. METHODS: As a group of analytical chemists, public health researchers, evaluators, and harm reductionists, we used a semi-structured guide to facilitate discussion of four different approaches for syringe service programs (SSPs) to offer drug checking services for supply-level monitoring. Using thematic analysis, we identified four key principles that SSPs should consider when implementing drug checking programs. RESULTS: A number of analytical methods exist for drug checking to contribute to supply-level monitoring. While there is likely not a one-size-fits-all approach, SSPs should prioritize methods that can (1) provide immediate utility to PWUD, (2) integrate seamlessly into existing workflows, (3) balance individual- and population-level data needs, and (4) attend to legal concerns for implementation and dissemination. CONCLUSIONS: Enhancing drug checking methods for supply-level monitoring has the potential to detect emerging threats in the drug supply and reduce the toll of the worsening overdose epidemic.


Assuntos
Overdose de Drogas , Assistência Farmacêutica , Humanos , Fentanila/análise , Analgésicos Opioides/análise , Overdose de Drogas/prevenção & controle , Overdose de Drogas/epidemiologia , Saúde Pública , Redução do Dano
2.
Harm Reduct J ; 20(1): 175, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38057832

RESUMO

BACKGROUND: Fentanyl test strips (FTS) are a commonly deployed tool in drug checking, used to test for the presence of fentanyl in street drug samples prior to consumption. Previous reports indicate that in addition to fentanyl, FTS can also detect fentanyl analogs like acetyl fentanyl and butyryl fentanyl, with conflicting reports on their ability to detect fentanyl analogs like Carfentanil and furanyl fentanyl. Yet with hundreds of known fentanyl analogs, there has been no large-scale study rationalizing FTS reactivity to different fentanyl analogs. METHODS: In this study, 251 synthetic opioids-including 214 fentanyl analogs-were screened on two brands of fentanyl test strips to (1) assess the differences in the ability of two brands of fentanyl test strips to detect fentanyl-related compounds and (2) determine which moieties in fentanyl analog chemical structures are most crucial for FTS detection. Two FTS brands were assessed in this study: BTNX Rapid Response and WHPM DanceSafe. RESULTS: Of 251 screened compounds assessed, 121 compounds were detectable at or below 20,000 ng/mL by both BTNX and DanceSafe FTS, 50 were not detectable by either brand, and 80 were detectable by one brand but not the other (n = 52 BTNX, n = 28 DanceSafe). A structural analysis of fentanyl analogs screened revealed that in general, bulky modifications to the phenethyl moiety inhibit detection by BTNX FTS while bulky modifications to the carbonyl moiety inhibit detection by DanceSafe FTS. CONCLUSIONS: The different "blind spots" are caused by different haptens used to elicit the antibodies for these different strips. By utilizing both brands of FTS in routine drug checking, users could increase the chances of detecting fentanyl analogs in the "blind spot" of one brand.


Assuntos
Overdose de Drogas , Drogas Ilícitas , Humanos , Analgésicos Opioides/farmacologia , Analgésicos Opioides/análise , Fentanila/farmacologia , Fentanila/análise , Drogas Ilícitas/análise
3.
Harm Reduct J ; 20(1): 87, 2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37420196

RESUMO

BACKGROUND: The opioid epidemic continues to be associated with high numbers of fatalities in the USA and other countries, driven mainly by the inclusion of potent synthetic opioids in street drugs. Drug checking by means of various technologies is being increasingly implemented as a harm reduction strategy to inform users about constituent drugs in their street samples. We assessed how valued drug checking services (DCS) would be for opioid street drug users given the ubiquity of fentanyl and related analogs in the drug supply, the information they would most value from drug checking, and compared expected versus actual constituent drugs in collected samples. METHODS: A convenience sample of opioid street drug users (N = 118) was recruited from two syringe service exchange programs in Chicago between 2021 and 2022. We administered brief surveys asking about overdose history, whether fentanyl was their preferred opioid, and interest in DCS. We also collected drug samples and asked participants what drug(s) they expected were in the sample. Provided samples were analyzed using LC-MS technology and the results compared to their expected drugs. RESULTS: Participants reported an average of 4.4 lifetime overdoses (SD = 4.8, range = 0-20) and 1.1 (SD = 1.8, range = 0-10) past-year overdoses. A majority (92.1%) believed they had recently used drugs containing fentanyl whether intentionally or unintentionally. Opinions about the desirability of fentanyl were mixed with 56.1% indicating they did not and 38.0% indicating they did prefer fentanyl over other opioids, mainly heroin. Attitudes toward DCS indicated a general but not uniform receptiveness with a majority indicating interest in DCS though sizeable minorities believed DCS was "too much trouble" (25.2%) or there was "no point" in testing (35.4%). Participants were especially inaccurate identifying common cutting agents and potentiating drugs such as diphenhydramine in their samples (sensitivity = .17). CONCLUSIONS: Results affirmed street drug users remain interested in using DCS to monitor their drugs and such services should be more widely available. Advanced checking technologies that provide information on the relative quantities and the different drugs present in a given sample available at point-of-care, would be most valuable but remain challenging to implement.


Assuntos
Overdose de Drogas , Usuários de Drogas , Drogas Ilícitas , Humanos , Analgésicos Opioides , Fentanila , Heroína , Overdose de Drogas/prevenção & controle , Overdose de Drogas/epidemiologia
4.
Forensic Chem ; 352023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37483533

RESUMO

An LC-MS/MS method for the analysis of 53 benzodiazepines, including various designer benzodiazepines, was developed. The developed method was applied to a total of 79 illicit street drug samples collected in Chicago, IL. Of these samples, 68 (84%) had detectable amounts of at least one benzodiazepine. Further, of the 53 benzodiazepines included in the developed method just 14 were measured in samples. Clonazolam, a potent designer benzodiazepine and derivative of clonazepam, was the most frequently measured benzodiazepine in 63% of samples and was measured in the highest concentrations. Other benzodiazepines measured in more than 10% of samples included clonazepam, alprazolam, flualprazolam, and oxazepam. Mixtures of benzodiazepines were frequently measured in samples, with just 24% of samples containing just one benzodiazepine. To determine the response of benzodiazepines on a rapid, point-of-use drug checking tool, all 53 benzodiazepine standards were screened on a lateral flow immunoassay benzodiazepine test strip. Sixty eight percent of standards gave a positive BTS response at a concentration of 20 µg/mL, demonstrating BTS have response to a wide variety of benzodiazepines, including many designer benzodiazepines. A comparison of this data to previous data reported for the same samples demonstrated all samples containing a benzodiazepine also had an opioid present, with fentanyl being present in 94% of benzodiazepine samples. These results highlight high rates of polysubstance drug presence in Chicago, IL illicit drug samples, posing an increased risk of drug overdoses in people who use drugs.

5.
Forensic Chem ; 332023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36910306

RESUMO

Drug checking services are being utilized worldwide to provide people who use drugs information on the composition and contents of their drugs as a tool for harm reduction and accidental overdose prevention. Existing drug checking services use a variety of techniques including immunoassay strips and spectroscopic techniques like FTIR and Raman. Few services utilize LC-MS based methods for primary or secondary analysis and few methods exist for direct analysis of illicit drugs. To address this, an LC-MS/MS method was developed for 22 illicit drugs and cutting agents using LC-MS/MS with application to 124 illicit drug samples that were collected from Chicago, IL. Samples were also analyzed using fentanyl and benzodiazepine immunoassay test strips. Fentanyl test strips gave a positive result for 86% of samples with only one sample showing a positive result on a benzodiazepine test strip. LC-MS/MS analysis of samples show that opioids were the most commonly quantified in 96% of samples, followed by stimulants at 12% and benzodiazepines at 1%. Fentanyl was measured in 91% of samples, co-occurring with heroin in 58% of opioid-containing samples. A comparison of the gold-standard LC-MS/MS results to fentanyl test strips shows a high level of accuracy for the fentanyl test strips, with just 5% of samples being classified as false negatives and no false positives. These results demonstrate the strengths and benefits of LC-MS/MS when incorporated as a secondary analysis tool for drug checking.

6.
ACS Appl Mater Interfaces ; 13(25): 29585-29601, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34137599

RESUMO

Highly dispersed iron-based quantum dots (QDs) onto powdered Vulcan XC-72R substrate were successfully electrodeposited by the rotating disk slurry electrodeposition (RoDSE) technique. Our findings through chemical physics characterization revealed that the continuous electron pathway interaction between the interface metal-carbon is controlled. The rotating ring-disk electrode (RRDE) and the prototype generation unit (PGU) of in-situ H2O2 generation in fuel cell experiments revealed a high activity for the oxygen reduction reaction (ORR) via two-electron pathway. These results establish the Fe/Vulcan catalyst at a competitive level for space and terrestrial new materials carriers, specifically for the in-situ H2O2 production. Transmission electron microscopy (TEM) analysis reveals the well-dispersed Fe-based quantum dots with a particle size of 4 nm. The structural and chemical-physical characterization through induced coupled plasma-optical emission spectroscopy (ICP-OES), transmission scanning electron microscopy (STEM), X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), and X-ray absorption spectroscopy (XAS); reveals that, under atmospheric conditions, our quantum dots system is a Fe2+/3+/Fe3+ combination. The QDs oxidation state tunability was showed by the applied potential. The obtention of H2O2 under the compatibility conditions of the drinking water resources available in the International Space Station (ISS) enhances the applicability of this iron- and carbon-based materials for in-situ H2O2 production in future space scenarios. Terrestrial and space abundance of iron and carbon, combined with its low toxicity and high stability, consolidates this present work to be further extended for the large-scale production of Fe-based nanoparticles for several applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...